SOP on Preventive maintenance of Vibro Sifter

0
12276

1.0 Objective:

To lay down a procedure for Preventive Maintenance of Vibro sifter.

2.0 Scope:

This SOP is applicable for the preventive maintenance of Vibro sifter to pharmaceutical formulation plant.

3.0 Responsibility:

3.1 Technician/above –Engg. Is responsible for Preventive Maintenance of Vibro sifter

4.0 Accountability:

4.1 Head- Engg. Shall be accountable for implementation and compliance of this SOP

5.0 Abbreviation

Not Applicable

6.0 Procedure:

6.1 Monthly:

6.1.1 Before carried out the preventive maintenance Switch off the incoming supply and display UNDER PREVENTIVE MAINTENANCE.

6.1.2 Check rugged spring for proper tight ness, rectify if any abnormality.

6.1.3 Check dead weight for proper fitting.

6.1.4 Lubricate the motor bearings.

6.1.5 Check wheels for free movement and it should lock proper if any abnormalities rectify it.

6.1.6 Check motor electrical terminals for proper tightness.

6.1.7 Check all gaskets for any damage, replace if required.

6.1.8 Check operation sifter for proper vibration if less vibration adjust the dead weight.

6.1.9 Record the details in attached annexure no.-I

7.0 List of Annexure / Format

7.1 Check list for Preventive maintenance of Vibro Sifter – I

8.0  References

8.1 SOP on SOPs.

8.2 Operating manual

9.0 History
         Date
    Revision Number
       Reason for revision
         –
         00
             New SOP

Annexure-I

Preventive Maintenance Record of Vibro sifter.

 

ID No. OF Equipment:  
Capacity:  
Area:  
Frequency: Monthly.

     Date:

Sr.

No.

CHECK POINTS STATUS
01 Check rugged spring for proper tightness, rectify if any abnormality.  
02

 

Check dead weight for proper fitting.  

 

03  Lubricate the motor bearings.  

 

04 Check wheels for free movement and it should lock proper if any abnormalities rectify it.  

 

05 Check motor electrical terminals for proper tightness.  
06 Check all gaskets for any damage, replace if required.  
07 Check operation sifter for proper vibration if less vibration adjust the dead weight.  

   

 

       Done By:                                                                                   Checked By